INSTALLATION
MANUAL
IP DOOR STATION N-8640DS
Designed to connect to the IP network, the N-8640DS is an
indoor use door station featuring high quality hands-free
conversation. It is equipped with 1 control input and 5
control outputs, allowing connections to a sensor, electronic
lock, and other external equipment. The N-8640DS can be
mounted either flush in a wall or on a wall by using the
designated mounting box.
The N-8640DS is in full conformity with IP65 water-proof
and dust-proof standards. The operating temperature range
is –10 to +50°C.
3. WALL MOUNTING
2. GENERAL DESCRIPTION
3.1. In-Wall Mounting
Mount the N-8640DS to
the YC-150 or electrical
box mounted in the wall.
Note
The wall should be over 12 mm thick, and the opening in the
wall for an electrical box should be under 115 mm (wide) by
162 mm (high).
3.2. On-Wall Mounting
N-8640DS
Machine screw M4 x 20 (accessory)
Wall
surface
YC-150 Back box (optional)
or 3-gang electrical box
Waterproof washer
(accessory)
The N-8640DS comes with 2 types of screws: machine
screw M4 x 20 and UNC No.6 x 20.
For the electrical box provided with unified threads, use the
oval head combination screws UNC No.6 x 20.
Accessory screws
Before installation or use, be sure to carefully read all the
instructions in this section for correct and safe operation.
Be sure to follow all the precautionary instructions in this
section, which contain important warnings and/or cautions
regarding safety.
After reading, keep this manual handy for future reference.
1. SAFETY PRECAUTIONS
CAUTION
Indicates a potentially hazardous situation which, if
mishandled, could result in moderate or minor personal
injury, and/or property damage.
Use the dedicated AC adapter or its equivalent for the unit.
Note that the use of other adapter may cause a fire.
Seal the panel edges.
N-8640DS's
front panel
Notes
• When controlling an electronic lock
with the N-8640DS unit, use "Torx"
screws to attach the unit at
installation so that it cannot be
detached easily.
• When installing the unit outdoors or
at locations where it gets wet with
water, tightly seal the panel edges.
Besides, provide a weep hole at the
underside of the mounting box to
permit water to drain off.
Mount the N-8640DS to the YS-13A Wall-mount box
mounted in the wall.
YS-13A
Rear plate
Install the YC-13A
with its rear plate
removed.
Make a weep hole (to allow water
to exit) in the bottom.
N-8640DS
Machine screw
M4 x 20
(accessory)
Wall
surface
Waterproof washer
(accessory)
The N-8640DS comes with 2 types of screws: machine
screw M4 x 20 and UNC No.6 x 20. Use the M4 x 20 screw.
Accessory screws
Notes
• When controlling an electronic lock with the N-8640DS
unit, use "Torx" screws to attach the unit at installation so
that it cannot be detached easily.
• When installing the unit outdoors or at locations where it
gets wet with water, tightly seal the edges of the panel and
those of the box's rear surface in contact with the wall
surface. Besides, make a weep hole (to allow water to
exit) in the YS-13A's bottom. (Refer to the figure shown
below.)
Wall surface
YS-13A
Seal the panel edges and
rear edges (on the wall side).
55
163.5
92
46
116.5
83.5
6-φ4.5
(for wall mounting)
4-M4
(for N-8640DS mounting)
Unit: mm
[YS-13A dimensional drawing]
Be sure to ground both the YC-150 or electrical box,
and the frame ground terminal on the unit's rear.
Doing otherwise may cause unit failure.
Be sure to ground the frame ground terminal on the
unit's rear. Doing otherwise may cause unit failure.
Page view 0
1 2

Summary of Contents

Page 1 - IP DOOR STATION N-8640DS

INSTALLATION MANUALIP DOOR STATION N-8640DSDesigned to connect to the IP network, the N-8640DS is anindoor use door station featuring high quality han

Page 2 - 4. WIRING

4. WIRING133-06-302-4BURL: http://www.toa.jp/ Network connection AC adapter connection• Power supply connection ( or )To an indi

Comments to this Manuals

No comments