OPERATING INSTRUCTIONS
POwER SUPPly mANAGER
VX-3000DS CE
VX-3000DS CE-GB
Thank you for purchasing TOA’s Power Supply Manager.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1134
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg, Germany
1134-CPR-137
14
DoP 14-001
EN 54-4: 1997/A1: 2002 + A2: 2006
VX-3000DS CE/CE-GB
Power supply equipment for fire detection and fire alarm systems for buildings
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - VX-3000DS CE-GB

OPERATING INSTRUCTIONSPOwER SUPPly mANAGERVX-3000DS CEVX-3000DS CE-GBThank you for purchasing TOA’s Power Supply Manager.Please carefully follow the i

Page 2

10 Step 1. Allow more than 10seconds to elapse after removing the powercords from the VX-3000DS'rear-mounted AC inlets (IN1 and I

Page 3 - 1. SAFETY PRECAUTIONS

11 Step 1. ConrmthatbatterypowerisnotinusebymeansoftheVX-3000DS'front-mountedBATTERYPOWERLED, which is unlit in this case. Step

Page 4 - 2. FEATURES

12[Fixing the battery] TocomplywithEN54-4,xthebatteryatthebottomplatesurfaceoftherackasshownbelow.Attach hook fasteners to the botto

Page 5 - 3. NOMENCLATURE AND FUNCTIONS

135. CONNECTIONS5.1. Connecting the VX-3000DS to VX-2000 SystemDS-SFLINK1228 V 4.8 ADC POWER INCH3 CH1CH4 CH2PA OUT (SP LINE)C HCH1C HCH2C HCH3C HCH4D

Page 6

145.2. Connecting the VX-3000DS to SX-2000 System5.2.1 When using a redundant power system*In this connection example, 2 power supply units are used.

Page 7 - View with the cover removed

155.2.2. When not using a redundant power systemRequiredpowerissuppliedtothesystemfromasinglepowersupplyunit.Connectthe[+]terminalof

Page 8 - 4. INSTALLATION

16[Cable termination]When connecting 2 power cables to a single terminal of the removable terminal plug, use a ferrule terminal with an insulation sle

Page 9 - Cable clamp

175.3. Connecting the VX-3000DS to VM-3000 SystemVX-3000DSVP-2241PA LINK VP-200VX28 V 4.8 ADC POWER INPA OUT (SP LINE)C HTEMPERATURESENSOR24V(16-25V)P

Page 10

185.3.1 Required number of VX-3000DS units in a 1-channel broadcasting systemThe required number of the VX-3000DS Power Supply Manager units is deter

Page 11

19[System including one VP amplifier connected as a standby amplifier]OneVX-3000DSisrequiredevery4VM-3360VA/3360Eampliersor6VM-3240VA/3240E

Page 12

2TABLE OF CONTENTS1. SAFETY PRECAUTIONS ... 32. FEATURES ...

Page 13 - 5. CONNECTIONS

20Belowisanexampleshowingthat2VX-3000DSunitsareusedinasystemincluding5VM-3240VA/3240Eampliers.[Required number of VX-3000DS units in

Page 14

216. CABLE USAGE TABLE[VX-3000DS]Terminal to Connect Cable Type Equipment to be Connected toTerminal NameEquipment ReceptaclePlug Cable Type Plug Equi

Page 15 - 250V

227. SWITCHING OFF SYSTEM POWER (DC)Connector Name• VX-3000DS' DS LINK ConnectionsDS LINK IN/OUTRJ45 Pin No.Orange/whiteShieldBrownBrown/whiteGre

Page 16

238. BLOCK DIAGRAMFuse T6.3A LFuse T6.3A LFuse T6.3A LDC Out 3DC Out 2DC Out 1POWER OUT 19-33 V MAX 5 ADC Output 3DC Output 2DC Output 1POWER OUT 19-3

Page 17 - PA OUT (SP LINE)

249. APPENDIX: Recommendations to the Power Supply InstallationIncorrect installations of the power supply manager VX-3000DS and its related equipme

Page 18 - DC POWER

25Battery ConnectionClean ContactsTake care that the connection terminals are clean before connecting the cables. Clean them if necessary.Ensure that

Page 19

26VX-3000DSThe power manager VX-3000DS monitors the availability of the AC power and switches on the battery in case of a total loss of that power. Wh

Page 20

27Trouble ShootingThe different faults described below are indicated on the front panel (Figure 4). Refer to the explanation below.AC POWER BATTERYIN1

Page 21 - 6. CABLE USAGE TABLE

28Check procedure 2:This measurement can be done with a slow voltmeter. DisconnecttheVAunit’spowersupplyfromtheDCoutputfromtheVX-3000DSan

Page 22 - DIPSW SETTING

29Power Source 220–230VAC,50/60HzPower Consumption 2800 W max. in total (at rated output with charging)650 W max. in total, 350 W max. each (EN6

Page 23 - 8. BLOCK DIAGRAM

31. SAFETY PRECAUTIONS• Beforeinstallationoruse,besuretocarefullyreadalltheinstructionsinthis sectionforcorrect andsafeoperation.•

Page 26 - VX-3000DS

URL:http://www.toa.jp/133-02-00037-02

Page 27 - Trouble Shooting

4• When connecting multiple appliances to a singlepower socket through a multi-outlet power strip, a total current consumption of the applianc

Page 28 - Measuring Points

53. NOMENCLATURE AND FUNCTIONS[Front]12 34 5 6AC POWER BATTERYIN1IN2POWERCONNECTCONDITIONPOWER SUPPLY MANAGER VX-3000DSCHECKCHARGING1. Power indicator

Page 29 - 10. SPECIFICATIONS

6[Fault indication]If any of the following indicators on the front panel remains unlit, the unit is judged failed. In such cases, remove the cause of

Page 30

7[Rear] 10. Functional earth terminal [SIGNAL GND]Hum noise may be generated when external equipment is connected to the unit. Connecting this termina

Page 31

84. INSTALLATION4.1. Installing the VX-3000DS in the Cabinet Rack4.2. Battery Installation• Takespecialcaretopreventthebatteryfrombeingshort

Page 32 - URL:http://www.toa.jp/

9• Strip the cable end long enough (30mm ±5 mm)to befully clamped. Otherwise, its outer jacket prevents the cable conductor from being t