Toa C-CC574 PL User Manual

Browse online or download User Manual for Safety Toa C-CC574 PL. Toa C-CC574 PL User Manual [fr] [de] [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - COMBINATION CAMERA

Thank you for purchasing TOA's combination camera. Please carefully follow the instructions in thismanual to ensure long, trouble-free use of you

Page 2 - TABLE OF CONTENTS

106. Align the positioning mark on the base unit with that on the camera unit.Align the marks4. Perform DIP SW settings on the camera unit.(For de

Page 3 - 1. SAFETY PRECAUTIONS

11NoteWhen mounting the camera unit to the base unit,mount it straight till it is attached to the base unitcorrectly. Mounting it at an angle may caus

Page 4

129. Tighten 2 camera unit mounting screws.10. Align the positioning mark on the ceiling mounting cover with that on the base unit.Ceiling mounting co

Page 5 - 4. HANDLING PRECAUTIONS

138. MOUNTING THE CAMERA TO A WEAK CEILING PANELUse the optional C-BC511C or C-BC511C-S Ceiling Mounting Cover and the optional C-BC511A CeilingMounti

Page 6

148.2. Mounting Procedures1. Make a mounting hole of ø140 mm in the ceiling panel.2. Install the anchor bolt for ceiling mounting bracket and anchor b

Page 7 - 5. NOMENCLATURE

158. For subsequent procedures, follow the steps 1 – 11 on p. 9 – 12.6. Attach the supplied safety wire to the base unit.7. Attach the safety wire con

Page 8 - 7. DIRECT CEILING MOUNTING

169. FLUSH CEILING MOUNTING• Use the optional C-BC511U or C-BC511U-S Flush Ceiling Mounting Bracket.• Flush mounting can be used to reduce the camera&

Page 9 - 7.2. Mounting Procedures

179.2. Mounting Procedures1. Make a mounting hole of ø230 mm in the ceiling panel.2. Install the anchor bolt for flush ceiling mounting bracket and an

Page 10 - Wire mounting bracket

186. Release the lock on the hinged portion of the base unit and run the video, transmission and power cablesextending from the ceiling through the fl

Page 11 - Mount straight

199. Perform steps 3 – 5 on p. 9 – 10.7. Place the flush ceiling mounting bracket in the ceiling behind the ceiling panel by inserting it through them

Page 12 - C-BC511C-S

2TABLE OF CONTENTS1. SAFETY PRECAUTIONS ... 32. GENERAL DESCRIPTION ...

Page 13 - 8.1. Mounting Example

2010. Attach the camera unit to the base unit.Align the positioning mark on the camera unit with that on the flush ceiling mounting bracket. Align the

Page 14 - 8.2. Mounting Procedures

2110. CEILING SUSPENSIONUse the optional C-BC511P Ceiling Suspension Bracket in combination with the optional C-BC511C or C-BC511C-S Ceiling Mounting

Page 15 - Use screws M3 x 8

224. Detach footings and saddle bracket on the camera mounting side from the suspension pipe.• Removed saddle brackets and screws are attached to the

Page 16 - 9. FLUSH CEILING MOUNTING

235. Attach the suspension pipe (saddle bracket and footing) to the suspension plate.Note: Ensure that the installed suspension pipe faces in the inte

Page 17 - 9.2. Mounting Procedures

2411. Attach the supplied safety wire to the base unit.Camera directionFootingM4 x 8 machine screw (supplied with the combination camera) 12. Attach r

Page 18

2513. Attach the safety wire attached to the base unit to the saddle bracket of the suspension pipe.14. Attach the base unit (with footing) to the sus

Page 19

26Top coverTabTabCamera directionTop cover15. Release the lock on the hinged portion of the base unit and connect the power, video, and signal cables

Page 20 - Align the notch

2711. WALL MOUNTINGUse the optional C-BC511W Wall Mounting Bracket and optional C-BC511C or C-BC511C-S, CeilingMounting Cover.NoteBe sure to use the s

Page 21 - 10. CEILING SUSPENSION

284. Perform steps 11 – 16 on p. 24 – 26.5. Attach the top cover. Insert one top cover's clicks into the other top cover's slots.Mount the t

Page 22 - 10.2. Mounting Procedures

2912.1. Precautions When Installing the Camera• Avoid install the camera cable in close proximity to other cables of electric products, such as fluore

Page 23

31. SAFETY PRECAUTIONS• Be sure to read the instructions in this section carefully before use.• Make sure to observe the instructions in this manual a

Page 24 - Oval hole

30NOCOMNCNOCOMNC[ Normal ][ Alarm ]Rated, Maximum permissible voltage: 20 V DC Permissible current limit: 1 AContact useful life: 100,000 times13.3. A

Page 25

31DIP SW1DIP SW2DIP SW313.4. DIP Switch SettingsNotes• Set the unused DIP switches to the "OFF" position. • If the DIP switches are not set

Page 26 - Camera direction

3213.4.1. Camera Address Setting Switch (DIP Switch 1: No. 1 – 8)Used to set camera address when using the camera in connection with the C-RM500 Remot

Page 27 - 11. WALL MOUNTING

33ON123456781173349ON12345678ON12345678ON12345678ON123456782183450ON12345678ON12345678ON12345678ON123456783193551ON12345678ON12345678ON12345678ON12345

Page 28

34ON1234567865 81 97 113ON12345678ON12345678ON12345678ON1234567866 82 98 114ON12345678ON12345678ON12345678ON1234567867 83 99 115ON12345678ON12345678ON

Page 29 - 12. CONNECTIONS

35ON12345678129 145 161 177ON12345678ON12345678ON12345678ON12345678130 146 162 178ON12345678ON12345678ON12345678ON12345678131 147 163 179ON12345678ON1

Page 30 - 13. CAMERA SETTINGS

36ON12345678193 209 225 241ON12345678ON12345678ON12345678ON12345678194 210 226 242ON12345678ON12345678ON12345678ON12345678195 211 227 243ON12345678ON1

Page 31 - 13.4. DIP Switch Settings

37Combination cameraOutdoor combination cameraMulti-switcherMonitorDedicated remote controller14. SYSTEM EXAMPLES

Page 32

38C-CC514 NT C-CC514 PL24 V AC, 50/ 60 Hz9 W (normal operation), 19 W max. (1.3 A max.)RS-485 communications system (applicable protocol: Type A, Type

Page 33

39C-CC564 NT C-CC564 PL24 V AC, 50/ 60 Hz9 W (normal operation), 19 W max. (1.3 A max.)RS-485 communications system (applicable protocol: Type A, Type

Page 34

4When Installing the Unit• To avoid electric shocks, be sure to switch off the power before power supply wiring work. Failure to do somay result in el

Page 35

40C-CC574 NT24 V AC, 50/ 60 Hz 9 W (normal operation), 19 W max. (1.3 A max)RS-485 communications system (applicable protocol: Type A, Type B)VBS 1.0

Page 36

41C-CC574 PL24 V AC, 50/ 60 Hz 9 W (normal operation), 19 W max. (1.3 A max)RS-485 communications system (applicable protocol: Type A, Type B)VBS 1.0

Page 37 - 14. SYSTEM EXAMPLES

42• AccessoriesSafety wire ... 1Camera mounting screw (machine

Page 39

133-05-405-9BURL: http://www.toa.jp/

Page 40

52. GENERAL DESCRIPTIONTOA’s dome-type color cameras combine with a high-speed camera drive that permits one 360-degreehorizontal rotation per second

Page 41

6• To clean, be sure to first unplug the power plug from the AC outlet, then wipe with a dry cloth. When the unitgets very dirty, use a cloth dampened

Page 42

7(1) Power supply terminal(2) Video output terminal (VIDEO OUT)(3) Connector (CN1)(4) Connector (CN2) *1(5) Safety wire(6) DIP switch (SW1)(7) DIP swi

Page 43

8Notes• Mount the camera to a heavy-duty ceiling surface (such as concrete ceiling).• When mounting directly to the ceiling (such as a double ceiling)

Page 44 - URL: http://www.toa.jp/

97.2. Mounting Procedures1. Mount the base unit to the ceiling.First fix two of the base unit mounting holes as shown below. Since no mounting screws

Comments to this Manuals

No comments