7.4.3. Protocol
Selects the type of camera control protocol (RS-485 communication).
1. Press the Menu key for 3 seconds or more to display the menu screen.
2. Tilt the joystick up or down to select "PROTOCOL," and confirm it with the SET key. The setting contents
will appear on Line 2.
3. Tilt the joystick left or right to select one of the following setting contents and confirm it with the SET key.
[Setting contents]
1. TYPE A
Select when connecting the type A communication controlled camera.
2. TYPE B
Select when connecting the type B communication controlled camera.
3. TYPE B ONE WAY
Select when controlling the Combination camera without receiving the response
from the camera. (Example: when controlling the Netcansee camera via a
network.)
Note: This will not ensure that combination cameras other than Netcansee
devices can be remotely controlled via communication network.
Note: The protocol type is set to "2. TYPE B" by the factory.
Notes
• For the controllable cameras, refer to p. 7, " About Controllable Equipment by the C-RM700."
• When "TYPE B ONE WAY" is selected;
C-CC514, C-CC564, C-CC574, C-CC714, C-CC764, and C-CC774:
Set the DIP SW2 No. 7 to the ON position. (Although the description of the DIP SW2 No. 7 is "Unused" in
the installation manual supplied with each camera, this setting is required when using the TYPE B ONE
WAY protocol.)
C-CC704:
Set the DIP SW No. 8 to the ON position. (Although the description of the DIP SW No. 8 is "Unused" in the
installation manual supplied with the C-CC704, this setting is required when using the TYPE B ONE WAY
protocol.)
In this “TYPE B ONE WAY” protocol, Auto-focus, Auxiliary 1, and Auxiliary 2 keys do not light. When a
camera to operate is selected during full-screen or multi-segment screen display, the control key always
lights regardless of the camera selected.
To stop each individual automatic operation, press the Auto-key while holding down the function key
assigned as a shift key.
To set each individual auxiliary contact to OFF, press each individual auxiliary key while holding down the
function key assigned as a shift key.
For the shift key setting, refer to p. 42, "Function."
PROTOCOL