14.4. General Control Input Terminal Connections
14.4.1. Controlling functions assigned to the General Control Input terminals from the external
equipment
Following are assignable functions to the General Control Input terminals. (For the function assignments, refer
to "General control input settings" in "Event Settings" in the separate software instruction manual.)
VA-INPUT 1 4: Allows general broadcast received from the designated input to the designated output
(zone).
EV 1 6: The designated pre-recorded general message announcement is automatically
broadcast to the designated output (zone).
Power ON/OFF*: Functions as the front-panel mounted Power switch by use of the control input.
Failure Receipt*: Acknowledges a failure and causes all currently sounding buzzers to stop. At the same
time, it switches the Failure indicator from flashing to steady on mode.
Failure output reset*: Resets the failure status.
External failure input*: Captures failure information having occurred outside the system by use of the control
input, causing the buzzers to sound in the VM-3000 system, and displaying the
information on the LCD screen.
* These functions can be used only when all the versions of VM-3000VA firmware, VM-3000E firmware, and
VM-3000 Setting Software are 2.00 or later.
VM-3240VA/3360VA/3240E/3360E rear
Input signal
Control activation
(only when the designated input signals
are assigned to the VA-Input 1 - 4.)
AWG 28 – 22