10.4.2. Failure acknowledgment
Perform failure acknowledgment at the VM-3360VA, VM-3240VA, or RM-320F, or by use of the control input.
Acknowledging a failure causes all currently sounding buzzers to stop. At the same time, the flashing yellow
Failure indicator light on the VM-3360VA or VM-3240VA or RM-320F will switch to steady on mode.
Note
Only the Failure indicator is switched from flashing to steady on mode when failures are acknowledged.
The Communications Failure indicator that flashes when a communications-related failure occurs will remain
flashing.
[Acknowledging failures at the VM-3240VA or VM-3360VA]
Press the [OK] key.
[Acknowledging failures at the RM-320F]
Press the Failure Acknowledgment key corresponding to the yellow flashing Failure indicator.
Notes
• The "Failure Acknowledgment" function must be assigned to the key in advance. If this function is not
assigned, the RM-320F cannot be used for failure acknowledgment.
• The acknowledgment function can be assigned using the setting software. (Refer to "Event Settings" "RM
Function Key Settings" "RM-320F Settings" in the separate software instruction manual.)
[OK] key
Failure
Acknowledgment
key
Failure indicator