[Alarm Output Terminal] (Pin Nos. 1
-
21)
The terminal of the number corresponding to the alarm-activated camera number shorts with the ground
terminal. Alarm output terminals 1
-
16 are the NPN open collector output.
Operating current: Maximum 20 V, 20 mA
[Alarm Output Terminal] (Pin No. 22)
This terminal is shorted with the ground terminal even when only one of the alarm input terminals receives an
alarm signal. The alarm output terminal is the NPN open collector output.
Operating current: Maximum 20 V, 20 mA
[Time Adjustment Input Terminal] (Pin No. 23) (Enables only when controlling the Type B protocol)
Shoring this terminal with the ground terminal causes the time synchronization command to be sent to the
Combination Camera. Set the time to receive a contact input in the "Time adjustment" setting. (Refer to p. 33,
"Time adjustment.")
Open voltage: 5 V DC, short circuit current: Maximum 5 mA
[Home Position Selection Input Terminal] (Pin No. 24)
2 channels of Home position can be programmed for the C-RM700.
When this terminal is in open state, the camera's operation follows the setting programmed for "1" in the
Home position settings, while it follows for "2" in the Home position settings if the terminal is being shorted
with the ground terminal. (Refer to p. 34, "Home position.")
Example: Use this terminal to switch the Home position in the daytime and nigh time.
Open voltage: 5 V DC, short-circuit current: Maximum 5 mA
[NC] (Pin No. 25)
Leave this pin unconnected.
Pin No. Function
Pin No. Function